
TEC TEC Item rate contract (rc) for annual supply of electrical items - supply & fixing of casing capping of following suitable size with screws, rawal plug etc. along, with all accessories complete in all respect on any hard surface/wall/trench/ceiling etc., complete as per instructions of eic., half inch (only supply), threefouth inch (only supply), 1inch (only supply), 1.25inch (only supply), 1.50inch (only supply), 2.0 inch (only supply), fixing of pvc conduit/ truncking. supply & fixing of pvc rigid conduit of following suitable, size with spacers & saddles screws, rawal plug etc. along with all accessories complete in all, respect on any hard surface/wall/trench/ceiling etc. compete as per instruction of eic., 12.5 mm (only supply), 20 mm (only supply), 25 mm (only supply), 32 mm (only supply), 40 mm (only supply), 50 mm (only supply), providing & fixing pvc trucking of following sizes along with all accessories complete in all, respect, all as directed by o-i-c, es., 50 x 50 x 2 mm (only supply), 100 x 50 x 2 mm (only supply), pvc flexible conduit supply & laying/replacement of pvc flexible conduit conforming to, isi standards & approved make with required number of coupling, pvc bushes, check nuts, etc complete all as per instruction of eic. in case of replacement, removed parts, items etc., shall be returned to actrec as it is., same as above 20 mm dia same as above (only supply), same as above 25 mm dia same as above(only supply), same as above 32 mm dia same as above(only supply), same as above 40 mm dia same as above(only supply), same as above 50 mm dia same as above(only supply), replacing the defective capacitor of table fan/ wall fan/ pedestal fan/ ceiling fan/ dip freezer, motor/street light fittings/fluorescent tube fittings or any other smilar application etc & testing, at site. general guidelines for replacement shall be as per item no 14.1 as applicable, all as, per instructions and as directed by e-i-c, es, 1.5 mfd (only supply), 2.5 mfd (only supply), 4 mfd (only supply), 5/6 mfd (only supply), 10/15/20 mfd (only supply), 40/50/60 mfd (only supply), supply, installation, testing & commissioning of dol starters, of reputed make make as per, the required capacity listed below with framework including connection with lugs etc., complete in all manners as per instruction of eic. in case of replacement removed parts shall, be handed pver to e-i-c, es along with gatepass/challans., up to 2 hp/1.5 kw single phase. (only supply), up to 7.5 hp/5.5 kw 3phase. (only supply), supply, installing of electrical consumable items with testing & commissioning of them as per, specifications & as per direction of engg-in-charge.in case of replacement/repairs, old, materials shall be handed over to e-i-c, es along with gatepass/challans etc. all replacements, are subjected to prior approval of o-i-c, es for any equivalent make, if make is not, mentioned.kindly refer make list provided separately). it may be noted that minimum balance, of these itmes are required to maintain on site for emerrgency use., 40 w fluorescent tube reputed make (only supply), 36 w fluorescent tube reputed make (only supply), 30 w germicidal fluorescent ulitrea-violet tube of reputed make (only supply), 36 w germicidal fluorescent ulitrea-violet light fixture with tube 4 feet (only supply), insect killer tube size 2 feet (only supply), insect killer tube size one and the half feet (only supply), 100 w gls clear/ milky lamp reputed make (only supply), 60 w gls clear/milky lamp reputed make (only supply), electronic choke for 36 w pll fitting (only supply), 40 w choke/ ballast reputed make (only supply), 20 w choke/ ballast reputed make (only supply), starter for fluorescent 36w tube light (only supply), led lamps pin type / thread type, fixing/replacement of 5/7/9w led lamp (only supply), fixing/replacement of 12w led lamp (only supply), g/replacement of 15w led lamp (only supply), fixing/replacement of 18w led lamp (only supply), fixing/replacement of 8w 2' long led tube (only supply), fixing/replacement of 35w led lamp (only supply), led driver, fixing/replacement of 3/5w led driver (only supply), fixing/replacement of 7/9w led driver (only supply), fixing/replacement of 12/15w led driver (only supply), fixing/replacement of 18/22w led driver (only supply), fixing/replacement of 24w led driver (only supply), fixing/replacement of 30w led driver (only supply), fixing/replacement of 36w led driver (only supply), gyesers/ heaters supply, installation, testing & commissining of various types of water, gyesers, heaters, heating coils, hot plates, strip heaters or any similar application heating, equipment as per the required specifications as per instructions & as directed by e-i-c, es. in, case of replacement/repairs, old items are to be handed over to e-i-c, es along with, gatepass/challans etc., 25 litre capacity , hospital use water heater(only supply), 3 litre capacity water geyser reputed brand/make (only supply), thermostats and heating coils., thermostat of good quality for all types of gysers (only supply), fixing/replacement of coil/tube type heaters for geysers1000 w (only supply), fixing/replacement of coil/tube type heaters for geysers1500 w (only supply), supply, installation, testing & commissioning of 1.1 kv grade pvc insulated stranded/ round, wire armoured copper/aluminium conductor power cables isi mark fixed on wall/ coloum/, ceiling or in shaft/existing trench on 5 mm thick spacers/ angle support fixed with screws/, coach screws/ anchor fasteners, all other fixing accessories etc. as per instruction of engg.-in, charge., 4 x 4 sq. mm copper conductor(only supply), 4 x 10 sq. mm copper conductor(only supply), gi pipes/foot valvessupply, installation gi pipes class b type with all fixing arrangement, such as couplings, bends etc on any kind of surface or below ground as per the instruction of, e-i-c., gi pipe 25 mm(only supply), gi pipe 32 mm(only supply), supply, installation, testing & commissioning of crone connector telephone tag block box, , fabricated out of 14 swg ms crca sheet mounted on ms frame of size 40 x 40 x 5 mm &, grouted on the wall/ fixed on the coloum free standing type with anchor fastener with front, openable hinged doors cam type locking arrangements, neoprene gasket for joints painting, with seven tank metal treatment process & with two coats of red oxide primer & two coats of, approved shade enamel paint, norm plate etc. as per the instruction of eic., 2 x 10 ways telephone tag block.only supply), 2 x 20 ways telephone tag block.only supply), cable glands and lugs supplying & erecting heavy duty flange type brass cable glands, for end jointing of various sizes for pvc armoured cable with brass washers, rubber rings, complete with cable ends & leads connected, with gland double earthing, work completed in, all respect all as per instructions and as directed by e-i-c, es, supplying & erecting heavy duty flange type brass cable glands for end jointing 2 to 4 core 2.5 sq., mm/ 2 to 4 core 6 sq. mm pvc armoured cable with brass washers, rubber rings complete with cable, ends & leads connected(only supply), as per item no 12.1. but for but 3 to 4 core x 6 sq. mm / 2 to 4 core x 10 sq. mm as per item no, 24.1 but for (only supply), as per item no 12.1 but for 3 to 4 core x 16 sq. mm / 3.5 to 4 core x 25 sq. mm / 3 x 35 sq.mmsame, as above(only supply), as per item no 12.1 but for 3.5x35sq.mm/3x50sq.mm same as above(only supply), as per item no 12.1 but for 3.5 x 50 sq.mm same as above(only supply), as per item no 12.1 but for 3.5 x 70 sq.mm same as above(only supply), as per item no 12.1 but for 3.5 x 95 sq.mm same as above(only supply), as per item no 12.1 but for 3.5 x 120 sq.mm same as above(only supply), as per item no 12.1 but for 3.5 x 150 sq.mm same as above(only supply), as per item no 12.1 but for 3.5 x 185 sq.mmsame as above(only supply), as per item no 12.1 but for 3.5 x 240 sq.mm same as above(only supply), lugs supplying & erecting at